Georgia access-control deployment

RBH UNC100 Controllers & Access Hardware

Controller and panel field installation, IP and door programming, power, I/O, firmware engineering assessment, troubleshooting and preventive maintenance.

RBH UNC100 two-door IP access controller
Certified RBH installerProduct supply & resaleProfessional field installationSoftware setupService & preventive maintenanceTechnical support

UNC100 and controller field installation

The UNC100 is a native TCP/IP two-door controller used with RBH software families. RBH publishes onboard battery charging, encrypted communications, programmable RS-485 and a PoE IEEE 802.3at variant. Compatibility includes Integra32, AxiomV and AxiomXa when the controller and firmware match the approved platform.

We install the enclosure and power, terminate readers and door devices, configure IP communications and firmware, enroll the controller in software and test all normal, alarm and offline conditions.

RBH UNC100 two-door IP access controller
The RBH UNC100 provides network-connected control for two access-controlled openings.
KSEDCO supplies, installs, configures, maintains, repairs, and supports these systems across Georgia. Discuss a site or service request

RBH hardware families and field scope

UNC100

Two-door IP controller available in conventional-power and PoE kit arrangements. Reader, lock, input, output, battery and network budgets are checked against the current field installation sheet.

UNC500 communications

Axiom enterprise systems can use UNC500 communications architecture. We verify the software edition, downstream controller topology, network system engineering and support status before expansion.

IRC/URC/NIRC families

Existing RBH sites may contain several controller generations. We identify exact boards, firmware and topology before recommending reuse, firmware conversion or replacement.

IOC8 and I/O

Input/output modules add alarm monitoring and relay control. Every point is labeled in the panel and software and included in cause-and-effect testing.

Elevator control

Floor relay control requires a coordinated scope with the elevator and fire-alarm teams, plus an exact matrix of credential, schedule and emergency behavior.

Power and enclosures

Lock current, auxiliary loads, battery runtime, grounding, branch protection, wire gauge and environmental conditions are calculated—not inferred from the number of doors.

Controller service and preventive maintenance

Health review

Inspect enclosure, supply and battery, board status, network errors, controller clocks, event upload, reader communications and recurring door alarms.

Corrective service

Isolate field wiring, reader, lock, input, power, network, firmware or software causes before replacing parts; then regression-test all affected openings.

Firmware engineering assessment

Use the RBH compatibility matrix for the exact management platform. Dealer-flashed or platform-specific firmware is handled only through approved channels with backup and rollback engineering assessment.

Closeout records

Update door schedules, IP and controller inventory, wiring labels, firmware, software release, battery date, test results and unresolved exceptions.

Official RBH hardware documentation

UNC100 product pageRBH hardware catalogField Installation guides and compatibility documents

Plan an installed and supported system

KSEDCO can review the openings, existing equipment, network, software, credential workflow and integration requirements before recommending a current configuration for the Georgia.